Exhaust gas incinerator manufacturers below analysis of incinerator common faults and causes
Release time:
2022-12-06
Waste gas incinerator manufacturersThe following analysis of common failures and causes of incinerators
Waste Gas Incinerator Manufacturers: Analysis of Common Faults and Causes of Incinerators
Incinerators often have some failures in operation. Don't worry. The following are the reasons for some failures summarized by waste gas incinerator manufacturers for your reference.
fire fault alarm

Waste gas incinerator manufacturersIt is believed that if flame occurs at the initial stage of ignition and light oil combustion stage, it may be that the oil level of the diesel tank is too low, the diesel contains water, the valve of the diesel system is not normally opened, the ignition electrode is faulty, the light oil nozzle is abnormal, the photosensitive resistor is not clean, and the smoke exhaust baffle cannot operate normally automatically.
2. High flue gas temperature (375 °) or high furnace temperature (1200 °) alarm and shutdown.
When burning solid waste, too much solid waste is filled. When burning dirty oil, the injection amount of dirty oil is too large, and the pressure of dirty oil or the speed of metering pump is appropriately reduced. The air intake of the furnace is too small, the air intake fan is abnormal or the air inlet is blocked. The exhaust baffle or exhaust fan is abnormal.
3. The dirty oil nozzle atomization is not good, the combustion is not good.
Serious carbon deposition in the furnace may be due to dirty nozzle, low oil pressure or insufficient atomization air.
4. The flame of the combustion chamber is unstable and the incinerator vibrates greatly.
The injection of dirty oil is unstable, the exhaust flue is dirty and blocked by carbon deposition, the exhaust fan or baffle is abnormal, the air inlet of the furnace is blocked, the fan blade is dirty and the bearing is damaged, etc.
Waste gas incinerator manufacturersWhat maintenance work needs to be done before burning?
Before incineration, the incinerator needs to be overhauled, mainly as follows:
Clean up the residual ash in the furnace and check the surface of the refractory bricks on the inner wall of the furnace. The air supply fan of the incinerator is located at the bottom of the incinerator, and air is supplied to the furnace through the four ports at the bottom of the furnace. Excessive garbage filling and excessive ash will block the air inlet.
Disassemble and clean the sewage pipeline. Two pneumatic valves are installed between the metering pump outlet and the fuel injector. The pneumatic valve is opened by the control air. The sealing material of the valve core is rubber, which is easy to deform under high oil temperature. After the dirty oil is cooled, the valve core The viscosity will increase, causing the valve core opening to be too small or even unable to open at all. The garbage in the dirty oil is easily blocked here. Therefore, the two pneumatic valves should be disassembled and checked before burning, the dirty oil and garbage cannot be injected normally after being blocked, and should be cleaned up before combustion.
Stop heating the dirty oil steam before incineration. When the dirty oil steam is cooled to 80, start the dirty oil pump for full circulation. Excessive temperature of the dirty oil is not conducive to the operation of the dirty oil pump, metering pump, pneumatic valve and other auxiliary equipment.
The above is the content of "Analysis of Common Faults and Causes of Incinerators" explained by the waste gas incinerator manufacturer. I believe everyone has a certain understanding. If you want to know more, you are welcome to contact our waste gas incinerator manufacturer. I hope the content explained above is helpful to everyone. Thank you for watching. I'll see you next time.