Cleaning Method of Finned Tube Heat Exchanger


Release time:

2022-08-04

Under normal circumstances, we can directly use high-pressure water to clean the finned tube heat exchanger, which is a physical cleaning method. The cleaning methods of finned tube heat exchanger mainly include manual cleaning, chemical cleaning and mechanical equipment cleaning. Compared with different cleaning methods, there are many advantages. First of all, the cleaning cost of finned tube heat exchangers is relatively low, that is, compared with its cleaning quality, and secondly, we need to understand that its cleaning speed is relatively fast. They generally do not pollute the environment. In addition, compared with everyone's mechanical equipment itself, it has virtually no corrosive irritation.
Secondly, what we actually need to know is that the ash accumulation of finned tube heat exchangers may directly reduce the thermal coefficient of heat transfer of the heat exchanger. Fouling increases energy and material consumption and reduces productivity. At this time, our finned tube heat exchangers reduce the impact of energy reduction on sanitary conditions through cleaning and descaling. Second, pay special attention to many factors. Compared with these mechanical equipment, they have many scales, scaling, deposits, corrosive products, etc.
How to improve the heat transfer capacity of the round tube? One of the effective methods is to expand the surface on the outer surface of the pipe, that is, the flue gas side, that is, the finned tube. Assuming that the actual heat transfer area of the finned tube is several times the outer surface of the original smooth tube, although the heat transfer coefficient of the flue gas is still very low, the heat transfer effect of the outer surface area of the smooth tube will be greatly improved, thereby enhancing the entire heat transfer process. Reduce the metal consumption of mechanical equipment and improve the economy under certain total heat transfer conditions.
Finned tube heat exchanger is a commonly used form of heat exchanger in refrigeration, air conditioning, chemical and other industries. The heat transfer resistance of finned tube heat exchanger is mainly concentrated on the fin side. Therefore, optimizing the fin side structure of heat exchanger is the key point to improve the performance of finned tube heat exchanger. The fin side of the finned tube evaporative heat exchanger used in room air conditioning basically operates under wet conditions.
When the finned tube heat exchanger is in a wet state and the surface temperature of the fin is lower than the dew point temperature of the wet air, the water vapor in the wet air begins to condense and precipitate on the surface of the fin. At this time, condensation droplets appear on the fin surface. With the continuous precipitation process, the droplets will gradually grow under the combined action of gravity and airflow traction and flow out of the fin surface.
The formation, growth and movement characteristics of condensate droplets on the fin surface have important and complex effects on the air side pressure drop and heat transfer of the finned tube heat exchanger, which need to be reflected in the optimization design of the air side structure of the heat exchanger. This requires simulation and calculation of condensation droplets on the surface of heat exchanger fins under wet analysis conditions.
In the past, the schemes for improving the heat transfer performance of heat exchangers mainly focused on the following two methods: one is to increase the heat transfer area as much as possible in a limited space, such as using small fin spacing; The other is to enhance heat transfer, through different means, to enhance the heat transfer capacity to a greater extent, such as adding vortex generators, using special-shaped tubes and other methods. The greater the resistance of the fluid through the heat exchanger, the more energy consumption of the heat exchanger.



Key words: